Autonomous temperature probes, data from the EMSO-Azores observatory, 2012-2013

Date 2018-08
Temporal extent 2012-07-13 -2013-08-26
Author(s) Barreyre ThibautORCID1, Cannat Mathilde2, Escartin JavierORCID2, Blandin Jerome3, Sarradin Pierre-Marie3
Affiliation(s) 1 : UiB, JC-DeepSea, Norway
2 : CNRS, IPGP, France
3 : IFREMER Institut Carnot EDROME, France
DOI 10.17882/56415
Publisher SEANOE
Keyword(s) Mid-Atlantic Ridge, EMSO-Azores, Hydrothermal Vents, Lucky Strike, Eiffel Tower, Capelinhos, Cimendef, Crystal, Isabel, Montsegur, Sintra, South Crystal, White Castle, Y3, WHOI, NKE, Temperature, Time-series, MoMAR, MoMARSAT2012
Abstract

This dataset contains temperature data acquired between July 2012 and August 2013 using 17 temperature probes (HTW, HTNKE and LTW) installed in smoker orifices or cracks. High-temperature WHOI probes (HTW) are composed of 2 J-type thermistors in the rod tip connected to 2 temperature data-loggers (named A & B), 2 data recordings are available for 1 HTW probe. They are able to record temperatures up to 415°C with an accuracy of ± 1.1°C, a resolution of 0.25°C at 375°C and a clock drift of 1min per month. High-temperature NKE probes (HTNKE) are able to record temperatures up to 450°C, with an accuracy of ±0.5°C, a resolution of 0.1°C and a clock drift of 1min/month. Low-temperature WHOI probes (LTW) are able to record temperatures up to 125°C. with an accuracy of ±0.22°C, a resolution of 0.025°C and a clock drift of ±1min per month. The array is not connected to an energy node. All probes are calibrated in time before deployment, probe time adjusted to UTC time. Temperature of probes is checked after recovery and before deployment. Clock drift after recovery is not implemented in data.

Licence CC-BY
Utilisation EMSO data are published without any warranty, express or implied. The user assumes all risk arising from his/her use of EMSO data. EMSO data are intended to be research-quality and include estimates of data quality and accuracy, but it is possible that these estimates or the data themselves contain errors. It is the sole responsibility of the user to assess if the data are appropriate for his/her use, and to interpret the data, data quality, and data accuracy accordingly. EMSO welcomes users to ask questions and report problems to the contact addresses listed in the data files or on the EMSO web page.
Data
File Size Format Processing Access
Sensor metadata 51 KB XLS, XLSX Open access
Data 5 MB CSV Raw data Open access
Top of the page

How to cite 

Barreyre Thibaut, Cannat Mathilde, Escartin Javier, Blandin Jerome, Sarradin Pierre-Marie (2018). Autonomous temperature probes, data from the EMSO-Azores observatory, 2012-2013. SEANOE. https://doi.org/10.17882/56415