Copy this text
COSTOF2, technical data from BOREL, node of the BOREL buoy, 2019-2020
This dataset contains technical parameters (Voltage in V, current in mA, energy in Ah, internal pressure in mbar, water leak detection). This log starts on june 21th 2019, stops on september 15th 2020 and is done by the COSTOF2 (COmmunication and STOrage Front-end). It is the Electronic core of BOREL the buoy that retrieve the data via satellite communication. It supports a weather station an a high resolution GPS. Two files are proposed, one for node V1 connected to the instruments, the other for the node V2 used for redundancy.
Disciplines
Chemical oceanography, Environment, Cross-discipline, Marine geology, Physical oceanography
Keywords
Mid-Atlantic Ridge, EMSO, Lucky Strike, Time-series, Biological monitoring node, MoMAR, BOREL, COSTOF
Location
23.676N, 23.676S, -32.278E, -32.278W
Devices
Parameters
Node V1 : Voltage, energy, water leak detection, current consumption, internal temperature and pressure, remaining storage space for each slot ID
- For each sensor board (that supports up to 3 sensors) : internal temperature, internal pressure, remaining storage
- Slot ID 8 : airmar WS200, Seabird Seaphox
- Slot ID 9 : Kanaton McMurdon (AIS), Leica GR25
Node V2 : Voltage, energy, water leak detection, current consumption, internal temperature and pressure, remaining storage space for each slot ID
- No sensor installed
Location
- Regional node: Emso-Azores
- Site: Lucky Strike
- Node: BOREL
- Coordinates: 23.676N, -32.278E
Installation
- Cruise: SARRADIN Pierre-Marie, CANNAT Mathilde (2017) MOMARSAT2019 cruise, RV Pourquoi pas ?, https://doi.org/10.17600/18001110
Recovery
- Cruise: Pierre Marie Sarradin - Ifremer / REM, Julien Legrand - Ifremer /REM - MOMARSAT2020 cruise, N/O Pourquoi Pas ? https://doi.org/10.17600/18000684
Operating parameters
- Measurement duration: 10 sec
- Sampling period: 240 minutes
Sensor metadata
- Type: Communication and Storage Front-end 2
- Provider: IFREMER
- Model: COSTOF2, BOREL version
Data management
- Real time data transmission: yes
- Data storage in the Communication and storage unit (COSTOF2): Full